Practice question · NEC Table 430.248
What Is the Full-Load Current of a 2 HP 120V Motor?
The full-load current of a 2 HP 120V motor is a straight table read. The stem says "table full-load current," and that phrase tells you exactly where to go. You open the single-phase motor table, find 2 HP, read across to the 120-volt column, and take the number the table gives you. That number is 24 amps. No calculation and no guessing.
Exam-style question (Sparky QOTD)
What is the table full-load current of a 2 HP, 120-volt, single-phase motor?
A. 24 amps
B. 20 amps
C. 12 amps
D. 17 amps
Answer: A) 24 amps. Table 430.248 lists 2 HP at 120V as 24 amps.
Where to Find It
Open your Code book to Table 430.248. That is the single-phase motor table. Find 2 HP, then read across to the 120-volt column. The value in that cell is 24 amps. Tab this table and label it clearly, because the table right next to it causes the most common miss on this question: Table 430.250 is the three-phase motor table, not this one.
Why This Is the Answer
Start with the two facts the stem hands you: single-phase and 120 volts. Single-phase sends you to Table 430.248. The tab-to-it note in the bank makes the split explicit: 430.248 is single-phase, 430.250 is three-phase. If you open the three-phase table for a single-phase motor, every number you read after that is wasted work, no matter how carefully you read it.
Now work the read itself. Horsepower first: find the 2 HP row. Voltage second: move across that row to the 120-volt column. The table gives you 24 amps, and that is option A. The bank explanation adds one pattern worth remembering: single-phase currents run roughly double the 240V column. That is why the 120-volt value looks high next to the smaller options. Lower voltage on a single-phase motor means a bigger current number in this table, and 24 amps fits that pattern.
Check the distractors against that read. The 12-amp option is the trap that fits the pattern in reverse: it is roughly half of 24, the kind of number you land on when the roughly-double relationship gets flipped in your head. The 20-amp and 17-amp options do not match the 2 HP, 120-volt cell at all. Only 24 amps is the value Table 430.248 actually prints for this motor. If you want the three-phase version of this same skill, work the 3 HP 230V motor question next.
Exam Tip
On any motor current question, check phase before you check horsepower. Say it out loud if you have to: single-phase, 430.248; three-phase, 430.250. Then check the voltage column before you read the number. Most misses on this question are not math misses. They are wrong-table and wrong-column misses, and both are fixed by slowing down for five seconds before you read a single value.
Keep Drilling
This is one of 33 NEC topics. Sparky's 1,087 codebook-first questions drill all of them — every question a lookup rep with your book open, 15 minutes a day.