What is required for stairway lighting with six risers is a control question, not a fixture question. When an interior stairway has six or more risers between floor levels, 210.70(A)(2) requires a wall switch at each floor level controlling the stairway lighting. Switch at the top, switch at the bottom, so no one crosses a dark stairway to reach the control.

Exam-style question (Sparky QOTD)

An interior stairway with six or more risers between floor levels requires ___.

A. an emergency light
B. a motion sensor only
C. a receptacle at the top
D. a wall switch at each floor level controlling the stairway lighting

Answer: D) a wall switch at each floor level controlling the stairway lighting. Section 210.70(A)(2) requires it for stairways with six or more risers.

Where to Find It

Open your Code book to Article 210, 210.70(A)(2). That section covers interior stairways with six or more risers between floor levels, and it requires a wall switch at each floor level controlling the stairway lighting. Tab Article 210 at 210.70 and write the bank note: six risers, switch top and bottom. The count in the stem is your trigger to open this section.

Why This Is the Answer

Read the stem for its two triggers. The stairway is interior, and it has six or more risers between floor levels. Section 210.70(A)(2) is written for exactly that condition, and its requirement is specific: a wall switch at each floor level, controlling the stairway lighting. Option D states that requirement word for word in plain form, which is why it is the answer.

The other options add devices the section does not require here. An emergency light is not the requirement stated in 210.70(A)(2) for this stairway. A motion sensor only does not replace the required wall switch at each floor level. A receptacle at the top answers a different kind of question entirely. The exam wants you to find the one control requirement the section actually imposes and not trade it for a device that sounds useful on a stairway.

The logic behind the rule helps you hold it. A switch at each floor level means you can turn the stairway lighting on before you use the stairs and off after you reach the other level. You never have to cross in the dark to find the only switch. When a stem gives you a riser count, treat it as a code trigger, not background detail. For another Article 210 dwelling rule, work the living room receptacle spacing question next.

Exam Tip

Circle the riser count in the stem. Six or more risers is the line that turns this section on. Below that count, this specific each-floor-level switch rule does not apply in the same way. On test day, a number buried in the stem is usually the trigger for the section, so train yourself to spot it before you read the options.