⚡ Sparky Pro: 7-day free trial — get it on Google Play and the App Store.

Practice question · NEC Table 430.248

What Is the Full-Load Current of a 5 HP 230V Motor?

The full-load current of a 5 HP 230V motor is a straight table read. The stem says table full-load current and single-phase, and those two phrases tell you exactly where to go. You open the single-phase motor table, find 5 HP, read across to the 230-volt column, and take the number the table gives you. That number is 28 amps.

Exam-style question (Sparky QOTD)

What is the table full-load current of a 5 HP, 230-volt, single-phase motor?

A. 40 amps
B. 17 amps
C. 15.2 amps
D. 28 amps

Answer: Answer: D) 28 amps. Table 430.248 lists a 5 HP single-phase motor at 230V as 28 amps.

Where to Find It

Open your Code book to Table 430.248. That is the single-phase motor table. Find the 5 HP row, then read across to the 230-volt column. The value in that cell is 28 amps. Tab this table and label it single-phase, because the table students confuse it with sits right in the same part of Article 430: Table 430.250 is the three-phase table. The bank's tab-to-it note is one line: 430.248 is single-phase, 430.250 is three-phase.

Why This Is the Answer

Start with the phase, because the phase picks the table. The stem says single-phase, so you are in Table 430.248 before you look at a single number. If you open Table 430.250 for this motor, every value you read after that is wasted work, no matter how carefully you read the row. The exam knows these two tables sit close together, and it writes single-phase stems to test whether you slow down long enough to pick the right one.

Now work the read itself. Horsepower first: find the 5 HP row. Voltage second: move across that row to the 230-volt column. The table gives you 28 amps, and that is option D. The bank explanation flags a coincidence worth knowing about: this 28 amps matches the 28A full-load current used in the motor breaker question by coincidence. Same number, different table. Do not let the familiar number talk you out of the read. The table in front of you is what makes it right.

Check the distractors against that read. The 40-amp, 17-amp, and 15.2-amp options do not match the 5 HP, 230-volt cell in Table 430.248. Only 28 amps is the value the table actually prints for this motor. If you want the smaller single-phase version of this same skill, work the 2 HP 120V motor question next.

Exam Tip

On any motor current question, check phase before you check horsepower. Say it out loud if you have to: single-phase, 430.248; three-phase, 430.250. Then check the voltage column before you read the number. Most misses on this question are not math misses. They are wrong-table and wrong-column misses, and both are fixed by slowing down for five seconds before you read a single value.

Keep Drilling

This is one of 33 NEC topics. Sparky's 1,087 codebook-first questions drill all of them — every question a lookup rep with your book open, 15 minutes a day.